Avantor® ACE® Excel® C4, HPLC/UHPLC Columns, Analytical, 5 µm
Supplier: Avantor
Certificates
About this item
These ultra-inert Avantor® ACE® Excel® C4 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 to 5 µm) and complementary phases available
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Specifications
- Catalog No:
- EXL-123-2546U
- EXL-123-7502U
- EXL-123-0203U
- EXL-123-0202U
- EXL-123-1546U
- EXL-123-1046U
- EXL-123-0502U
- Environmentally Preferable:
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Carbon load:
- 5,5%
- 5,5%
- 5,5%
- 5,5%
- 5,5%
- 5,5%
- 5,5%
- Endcapped:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Max. pressure:
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- pH range:
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- Surface area:
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- USP code:
- L26
- L26
- L26
- L26
- L26
- L26
- L26
- Environmental certification:
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
Specifications
Product Information
- Catalog #Column FormatPhasePore sizeParticle SizeØ int.LengthPkAvailabilityPrice
- Local Article Number: ACETEXL-123-0202USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-123-0502UAnalyticalC4100 Å5 µm2,10 mm50 mm11 * 1 KS18 930,00 KčLocal Article Number: ACETEXL-123-0502USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - Local Article Number: ACETEXL-123-7502USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-123-0203UAnalyticalC4100 Å5 µm3,00 mm20 mm11 * 1 KS64 360,00 KčLocal Article Number: ACETEXL-123-0203USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - Local Article Number: ACETEXL-123-1046USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - Local Article Number: ACETEXL-123-1546USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-123-2546UAnalyticalC4100 Å5 µm4,60 mm250 mm11 * 1 KS26 080,00 KčLocal Article Number: ACETEXL-123-2546USpecifications:
Low Manufacturing Impact More
Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load5,5%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL26Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact
Guard cartridges
Product Information
- Catalog #SeqDescriptionColumn FormatPhasePore sizeParticle SizePkAvailabilityPrice
- 106For analytical columns (I-Ø 3,0, 4,0, 4,6 mm)Guard cartridgeC4 (Butyl)100 Å5 µm5Log in for availabilityLocal Article Number: ACETACE-123-0103GD
Cartridge holders and accessories
Product Information
- Catalog #DescriptionPkAvailabilityPrice
- Local Article Number: ACETC0001