Czech Republic
Order Entry
VWR® XT⁹⁶ XTender⁹⁶, Thermal Cyclers
VWR® XT⁹⁶ XTender⁹⁶, Thermal Cyclers
 
undefined
VWR® XT⁹⁶ XTender⁹⁶, Thermal Cyclers

 

  • Catalog No:
  • 732-3658
  • 732-3657
  • 732-1359
  • 732-3428
  • Model:
  • XTender⁹⁶ Gradient
  • XTender⁹⁶
  • XT⁹⁶
  • XT⁹⁶ Gradient
  • Block homogeneity:
  • ±0,35 °C at 72 °C
  • ±0,35 °C at 72 °C
  • ±0,35 °C at 72 °C
  • ±0,35 °C at 72 °C
  • Cooling:
  • 8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
  • 8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
  • 8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
  • 8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
  • Cooling ramp rate:
  • Max. 4 °C/s
  • Max. 4 °C/s
  • Max. 4 °C/s
  • Max. 4 °C/s
  • Gradient:
  • +
  • -
  • -
  • +
  • Gradient temperature range:
  • +30...100 °C (±0,2 °C)
  • -
  • -
  • +30...100 °C (±0,2 °C)
  • Max. gradient:
  • 30 °C (±15 °C)
  • -
  • -
  • 30 °C (±15 °C)
  • Heating ramp rate:
  • Max. 4 °C/s
  • Max. 4 °C/s
  • Max. 4 °C/s
  • Max. 4 °C/s
  • Interfaces:
  • 2× USB, 1× Ethernet (MS Windows®, Linux) for remote control via PC software and XT96 primary unit
  • 2× USB, 1× Ethernet (MS Windows®, Linux) for remote control via PC software and XT96 primary unit
  • 2× USB, 1× Ethernet (MS Windows®, Linux), remote control and monitoring of instruments via PC software and primary/secondary control
  • 2× USB, 1× Ethernet (MS Windows®, Linux), remote control and monitoring of instruments via PC software and primary/secondary control
  • Lid:
  • Automatic height adjustment
  • Automatic height adjustment
  • Automatic height adjustment
  • Automatic height adjustment
  • Lid temperature range:
  • +40...110 °C
  • +40...110 °C
  • +40...110 °C
  • +40...110 °C
  • No. of programs:
  • 500000
  • 500000
  • 500000
  • 500000
  • Sample capacity:
  • 96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
  • 96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
  • 96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
  • 96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
  • Software:
  • Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure and MP3 signal tones
  • Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure and MP3 signal tones
  • Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure; MP3 signal tones; primary/secondary control
  • Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure; MP3 signal tones; primary/secondary control
  • Temperature range:
  • +4...105 °C
  • +4...105 °C
  • +4...105 °C
  • +4...105 °C
  • W×D×H:
  • 220×330×190 mm
  • 220×330×190 mm
  • 220×330×310 mm
  • 220×330×310 mm
  • Weight:
  • 8,3 kg (including block)
  • 8,3 kg (including block)
  • 8,9 kg (including block)
  • 8,9 kg (including block)

 

 

  •  
    Pk
     
     
  • Thermal cycler, XT96, with 96-well block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates
    Thermal cycler, XT96, with 96-well block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates
    732-1359
    1
       
       
    1 * 1 KS
    1 * 1 KS - 123 880,00 Kč
    123 880,00 Kč
    1 * 1 KS
       123 880,00 Kč

     
     
    Accessories
    Specifications
    Model
    XT⁹⁶
    Environmentally Preferable
    Block homogeneity
    ±0,35 °C at 72 °C
    Cooling
    8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
    Cooling ramp rate
    Max. 4 °C/s
    Gradient
    -
    Gradient temperature range
    -
    Max. gradient
    -
    Heating ramp rate
    Max. 4 °C/s
    Interfaces
    2× USB, 1× Ethernet (MS Windows®, Linux), remote control and monitoring of instruments via PC software and primary/secondary control
    Lid
    Automatic height adjustment
    Lid temperature range
    +40...110 °C
    No. of programs
    500000
    Sample capacity
    96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
    Software
    Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure; MP3 signal tones; primary/secondary control
    Temperature range
    +4...105 °C
    W×D×H
    220×330×310 mm
    Weight
    8,9 kg (including block)
  • Gradient thermal cycler, XT96 Gradient, with 96-well gradient block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates
    Gradient thermal cycler, XT96 Gradient, with 96-well gradient block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates
    732-3428
    1
       
       
    1 * 1 KS
    1 * 1 KS - 134 080,00 Kč
    134 080,00 Kč
    1 * 1 KS
       134 080,00 Kč

     
     
    Accessories
    Specifications
    Model
    XT⁹⁶ Gradient
    Environmentally Preferable
    Block homogeneity
    ±0,35 °C at 72 °C
    Cooling
    8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
    Cooling ramp rate
    Max. 4 °C/s
    Gradient
    +
    Gradient temperature range
    +30...100 °C (±0,2 °C)
    Max. gradient
    30 °C (±15 °C)
    Heating ramp rate
    Max. 4 °C/s
    Interfaces
    2× USB, 1× Ethernet (MS Windows®, Linux), remote control and monitoring of instruments via PC software and primary/secondary control
    Lid
    Automatic height adjustment
    Lid temperature range
    +40...110 °C
    No. of programs
    500000
    Sample capacity
    96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
    Software
    Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure; MP3 signal tones; primary/secondary control
    Temperature range
    +4...105 °C
    W×D×H
    220×330×310 mm
    Weight
    8,9 kg (including block)
  • Thermal cycler, XTender96 - without touch screen, with 96-well block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates - controlled by PC/Tablet or from another XT96 thermal cycler
    Thermal cycler, XTender96 - without touch screen, with 96-well block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates - controlled by PC/Tablet or from another XT96 thermal cycler
    732-3657
    1
       
       
    1 * 1 KS
    1 * 1 KS - 105 390,00 Kč
    105 390,00 Kč
    1 * 1 KS
       105 390,00 Kč

     
     
    Accessories
    Specifications
    Model
    XTender⁹⁶
    Environmentally Preferable
    Block homogeneity
    ±0,35 °C at 72 °C
    Cooling
    8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
    Cooling ramp rate
    Max. 4 °C/s
    Gradient
    -
    Gradient temperature range
    -
    Max. gradient
    -
    Heating ramp rate
    Max. 4 °C/s
    Interfaces
    2× USB, 1× Ethernet (MS Windows®, Linux) for remote control via PC software and XT96 primary unit
    Lid
    Automatic height adjustment
    Lid temperature range
    +40...110 °C
    No. of programs
    500000
    Sample capacity
    96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
    Software
    Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure and MP3 signal tones
    Temperature range
    +4...105 °C
    W×D×H
    220×330×190 mm
    Weight
    8,3 kg (including block)
  • Gradient thermal cycler, XTender96 Gradient - without touch screen, with 96-well gradient block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates - controlled by PC/Tablet or from another XT96 thermal cycler
    Gradient thermal cycler, XTender96 Gradient - without touch screen, with 96-well gradient block and standard lid, for 96×0,2 ml tubes or 96-well PCR plates - controlled by PC/Tablet or from another XT96 thermal cycler
    732-3658
    1
       
       
    1 * 1 KS
    1 * 1 KS - 114 770,00 Kč
    114 770,00 Kč
    1 * 1 KS
       114 770,00 Kč

     
     
    Accessories
    Specifications
    Model
    XTender⁹⁶ Gradient
    Environmentally Preferable
    Block homogeneity
    ±0,35 °C at 72 °C
    Cooling
    8 Peltier elements per block, with long-life technology, and 8 control circuits with PT1000 temperature sensors
    Cooling ramp rate
    Max. 4 °C/s
    Gradient
    +
    Gradient temperature range
    +30...100 °C (±0,2 °C)
    Max. gradient
    30 °C (±15 °C)
    Heating ramp rate
    Max. 4 °C/s
    Interfaces
    2× USB, 1× Ethernet (MS Windows®, Linux) for remote control via PC software and XT96 primary unit
    Lid
    Automatic height adjustment
    Lid temperature range
    +40...110 °C
    No. of programs
    500000
    Sample capacity
    96×0,2 ml tubes or 96-well PCR plates (non- or semi-skirted only)
    Software
    Graphical or tabular programming; 'Global Program Ramp'; 'Tube Control'; online help; 'Quick Start' function and 'Power Fail Denaturation' for auto-restart after power failure and MP3 signal tones
    Temperature range
    +4...105 °C
    W×D×H
    220×330×190 mm
    Weight
    8,3 kg (including block)